1/*
2 * Copyright (C) 2011 Samsung Electronics Co., Ltd.
3 * MyungJoo.Ham <myungjoo.ham@samsung.com>
4 *
5 * Charger Manager.
6 * This framework enables to control and multiple chargers and to
7 * monitor charging even in the context of suspend-to-RAM with
8 * an interface combining the chargers.
9 *
10 * This program is free software; you can redistribute it and/or modify
11 * it under the terms of the GNU General Public License version 2 as
12 * published by the Free Software Foundation.
13**/
14
15#ifndef _CHARGER_MANAGER_H
16#define _CHARGER_MANAGER_H
17
18#include <linux/power_supply.h>
19#include <linux/extcon.h>
20#include <linux/alarmtimer.h>
21
22enum data_source {
23	CM_BATTERY_PRESENT,
24	CM_NO_BATTERY,
25	CM_FUEL_GAUGE,
26	CM_CHARGER_STAT,
27};
28
29enum polling_modes {
30	CM_POLL_DISABLE = 0,
31	CM_POLL_ALWAYS,
32	CM_POLL_EXTERNAL_POWER_ONLY,
33	CM_POLL_CHARGING_ONLY,
34};
35
36enum cm_event_types {
37	CM_EVENT_UNKNOWN = 0,
38	CM_EVENT_BATT_FULL,
39	CM_EVENT_BATT_IN,
40	CM_EVENT_BATT_OUT,
41	CM_EVENT_BATT_OVERHEAT,
42	CM_EVENT_BATT_COLD,
43	CM_EVENT_EXT_PWR_IN_OUT,
44	CM_EVENT_CHG_START_STOP,
45	CM_EVENT_OTHERS,
46};
47
48/**
49 * struct charger_cable
50 * @extcon_name: the name of extcon device.
51 * @name: the name of charger cable(external connector).
52 * @extcon_dev: the extcon device.
53 * @wq: the workqueue to control charger according to the state of
54 *	charger cable. If charger cable is attached, enable charger.
55 *	But if charger cable is detached, disable charger.
56 * @nb: the notifier block to receive changed state from EXTCON
57 *	(External Connector) when charger cable is attached/detached.
58 * @attached: the state of charger cable.
59 *	true: the charger cable is attached
60 *	false: the charger cable is detached
61 * @charger: the instance of struct charger_regulator.
62 * @cm: the Charger Manager representing the battery.
63 */
64struct charger_cable {
65	const char *extcon_name;
66	const char *name;
67
68	/* The charger-manager use Exton framework*/
69	struct extcon_specific_cable_nb extcon_dev;
70	struct work_struct wq;
71	struct notifier_block nb;
72
73	/* The state of charger cable */
74	bool attached;
75
76	struct charger_regulator *charger;
77
78	/*
79	 * Set min/max current of regulator to protect over-current issue
80	 * according to a kind of charger cable when cable is attached.
81	 */
82	int min_uA;
83	int max_uA;
84
85	struct charger_manager *cm;
86};
87
88/**
89 * struct charger_regulator
90 * @regulator_name: the name of regulator for using charger.
91 * @consumer: the regulator consumer for the charger.
92 * @externally_control:
93 *	Set if the charger-manager cannot control charger,
94 *	the charger will be maintained with disabled state.
95 * @cables:
96 *	the array of charger cables to enable/disable charger
97 *	and set current limit according to constratint data of
98 *	struct charger_cable if only charger cable included
99 *	in the array of charger cables is attached/detached.
100 * @num_cables: the number of charger cables.
101 * @attr_g: Attribute group for the charger(regulator)
102 * @attr_name: "name" sysfs entry
103 * @attr_state: "state" sysfs entry
104 * @attr_externally_control: "externally_control" sysfs entry
105 * @attrs: Arrays pointing to attr_name/state/externally_control for attr_g
106 */
107struct charger_regulator {
108	/* The name of regulator for charging */
109	const char *regulator_name;
110	struct regulator *consumer;
111
112	/* charger never on when system is on */
113	int externally_control;
114
115	/*
116	 * Store constraint information related to current limit,
117	 * each cable have different condition for charging.
118	 */
119	struct charger_cable *cables;
120	int num_cables;
121
122	struct attribute_group attr_g;
123	struct device_attribute attr_name;
124	struct device_attribute attr_state;
125	struct device_attribute attr_externally_control;
126	struct attribute *attrs[4];
127
128	struct charger_manager *cm;
129};
130
131/**
132 * struct charger_desc
133 * @psy_name: the name of power-supply-class for charger manager
134 * @polling_mode:
135 *	Determine which polling mode will be used
136 * @fullbatt_vchkdrop_ms:
137 * @fullbatt_vchkdrop_uV:
138 *	Check voltage drop after the battery is fully charged.
139 *	If it has dropped more than fullbatt_vchkdrop_uV after
140 *	fullbatt_vchkdrop_ms, CM will restart charging.
141 * @fullbatt_uV: voltage in microvolt
142 *	If VBATT >= fullbatt_uV, it is assumed to be full.
143 * @fullbatt_soc: state of Charge in %
144 *	If state of Charge >= fullbatt_soc, it is assumed to be full.
145 * @fullbatt_full_capacity: full capacity measure
146 *	If full capacity of battery >= fullbatt_full_capacity,
147 *	it is assumed to be full.
148 * @polling_interval_ms: interval in millisecond at which
149 *	charger manager will monitor battery health
150 * @battery_present:
151 *	Specify where information for existance of battery can be obtained
152 * @psy_charger_stat: the names of power-supply for chargers
153 * @num_charger_regulator: the number of entries in charger_regulators
154 * @charger_regulators: array of charger regulators
155 * @psy_fuel_gauge: the name of power-supply for fuel gauge
156 * @thermal_zone : the name of thermal zone for battery
157 * @temp_min : Minimum battery temperature for charging.
158 * @temp_max : Maximum battery temperature for charging.
159 * @temp_diff : Temperature diffential to restart charging.
160 * @measure_battery_temp:
161 *	true: measure battery temperature
162 *	false: measure ambient temperature
163 * @charging_max_duration_ms: Maximum possible duration for charging
164 *	If whole charging duration exceed 'charging_max_duration_ms',
165 *	cm stop charging.
166 * @discharging_max_duration_ms:
167 *	Maximum possible duration for discharging with charger cable
168 *	after full-batt. If discharging duration exceed 'discharging
169 *	max_duration_ms', cm start charging.
170 */
171struct charger_desc {
172	const char *psy_name;
173
174	enum polling_modes polling_mode;
175	unsigned int polling_interval_ms;
176
177	unsigned int fullbatt_vchkdrop_ms;
178	unsigned int fullbatt_vchkdrop_uV;
179	unsigned int fullbatt_uV;
180	unsigned int fullbatt_soc;
181	unsigned int fullbatt_full_capacity;
182
183	enum data_source battery_present;
184
185	const char **psy_charger_stat;
186
187	int num_charger_regulators;
188	struct charger_regulator *charger_regulators;
189
190	const char *psy_fuel_gauge;
191
192	const char *thermal_zone;
193
194	int temp_min;
195	int temp_max;
196	int temp_diff;
197
198	bool measure_battery_temp;
199
200	u32 charging_max_duration_ms;
201	u32 discharging_max_duration_ms;
202};
203
204#define PSY_NAME_MAX	30
205
206/**
207 * struct charger_manager
208 * @entry: entry for list
209 * @dev: device pointer
210 * @desc: instance of charger_desc
211 * @fuel_gauge: power_supply for fuel gauge
212 * @charger_stat: array of power_supply for chargers
213 * @tzd_batt : thermal zone device for battery
214 * @charger_enabled: the state of charger
215 * @fullbatt_vchk_jiffies_at:
216 *	jiffies at the time full battery check will occur.
217 * @fullbatt_vchk_work: work queue for full battery check
218 * @emergency_stop:
219 *	When setting true, stop charging
220 * @psy_name_buf: the name of power-supply-class for charger manager
221 * @charger_psy: power_supply for charger manager
222 * @status_save_ext_pwr_inserted:
223 *	saved status of external power before entering suspend-to-RAM
224 * @status_save_batt:
225 *	saved status of battery before entering suspend-to-RAM
226 * @charging_start_time: saved start time of enabling charging
227 * @charging_end_time: saved end time of disabling charging
228 */
229struct charger_manager {
230	struct list_head entry;
231	struct device *dev;
232	struct charger_desc *desc;
233
234#ifdef CONFIG_THERMAL
235	struct thermal_zone_device *tzd_batt;
236#endif
237	bool charger_enabled;
238
239	unsigned long fullbatt_vchk_jiffies_at;
240	struct delayed_work fullbatt_vchk_work;
241
242	int emergency_stop;
243
244	char psy_name_buf[PSY_NAME_MAX + 1];
245	struct power_supply_desc charger_psy_desc;
246	struct power_supply *charger_psy;
247
248	u64 charging_start_time;
249	u64 charging_end_time;
250};
251
252#ifdef CONFIG_CHARGER_MANAGER
253extern void cm_notify_event(struct power_supply *psy,
254				enum cm_event_types type, char *msg);
255#else
256static inline void cm_notify_event(struct power_supply *psy,
257				enum cm_event_types type, char *msg) { }
258#endif
259#endif /* _CHARGER_MANAGER_H */
260